E6582062
3. [Basic operation] Operation panel and screen display 3-14
3
9
Switching of backlight color
When you press the [F3] key ( mark), you can
change the color of the backlight to white or red.
The color is switched every time you press the key.
LCD version and Language version
You can check the version of the LCD body at the bot-
tom of the screen.
3. 1. 4 Copy function
When you press the [F2] key ("Copy") in [Standard mode], the copy function screen is displayed.
The copy function allows you to upload/download the parameters of the inverter to/from the file (mem-
ory) of the LCD body.
<Limitations>
Copying cannot be executed between inverters with different capacities.
Re-upload the file if you want to use parameters added with version upgrade.
Up to 16 files can be stored. Since the 17th file cannot be created, overwrite with the same file
name.
Memo
The LCD screen can be set regardless of the setting of inhibition of parameter change with
<F700: Parameter reading&writing access lockout>.
Mandatory
action
The copy function cannot be used during run. Use this function when the inverter is stopped.
Never turn off the power of the body or attach/remove the LCD during copying. Otherwise, the
memory in the LCD may be damaged, and repair (service call) may be required.
Language select
Data/Time setting
Screen contrast
Standby
LCD version
Top Language
Monitor
0.0HzSTOP
17:14
2016/06/01
50%
3min
V1.3IE44
LCD screen setting
Data/Time setting
Screen contrast
Standby
LCD version
Language version
Top Language Monitor
0.0HzSTOP
16:31
2016/7/06
50%
3min
V1.3IE44
U1.10
LCD screen setting
F R

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m

Related product manuals