EasyManuals Logo

Toshiba TOSVERT VF-AS3 User Manual

Toshiba TOSVERT VF-AS3
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #233 background image
E6582062
5-67 5. [Fundamental operation] How to use parameters
3
4
5
9
5. 4. 2 Restarting smoothly after momentary power failure
<F301: Auto-restart>
Function
The motor that is coasting due to momentary power failure is accelerated immediately after the
power is restored (auto-restart function).
In addition, this parameter detects the motor speed and direction of rotation of the motor during
coasting at the time of startup, and allows switching from commercial power operation to inverter
operation without stopping the motor(motor speed search function).
Parameter setting
Selecting a setting value
1: Power failure
The motor that is coasting due to momentary power failure is accelerated immediately after the
power is restored.
It is operated after power is restored after power circuit undervoltage is detected. Turn on the run
command.
CAUTION
Mandatory
action
When the auto-restart after momentary stop function is selected, stand clear of motors and
machines at momentary power failure.
The motors and machines which have stopped due to momentary power failure will restart
suddenly after power is restored, and this will result in injury.
Attach caution labels indicating functions programmed for Auto restart, on inverters, motors and
machines.
Please prevent accidents with the caution labels.
Title Parameter name Adjustment range
Default
setting
F301 Auto-restart 0: Disabled
1: Power failure
2: Terminal ST On/Off
3: Terminal ST On/Off or power failure
4: At startup
0
0.0HzSTOP
15:35
F301 : Auto-restart
0: Disabled
1: Power failure
2: Terminal ST On/Off
3: ST On/Off or power failure
4: At startup

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m

Related product manuals