4 WSHP-SVX01L-EN
Model Number Descriptions: ½–25 Ton (GEH/GEV)
Digit 1, 2 & 3 - Unit
Configuration
GEH = Horizontal
GEV = Vertical
Digit 4 - Development Sequence
E = Development
Digit 5, 6, & 7 - Nominal
Capacity
006 = ½ Ton
009 = ¾ Ton
012 = 1 Ton
015 = 1¼ Ton
018 = 1½ Ton
024 = 2 Ton
030 = 2½ Ton
032 = 2 2/3 Ton
036 = 3 Ton
040 = 3 1/3 Ton
042 = 3½ Ton
048 = 4 Ton
060 = 5 Ton
072 = 6 Ton
090 = 7½ Ton
120 = 10 Ton
150 = 12½ Ton
180 = 15 Ton
240 = 20 Ton
300 = 25 Ton
Digit 8 - Unit Voltage
0 = 115/60/1
1 = 208/60/1
2 = 230/60/1
3 = 208/60/3
4 = 460/60/3
5 = 575/60/3
6 = 220-240/50/1
7 = 265/60/1
8 = 230/60/3
9 = 380-415/50/3
Digit 9 - Heat Exchanger
1 = Copper Water Coil(s)
2 = Cupro-Nickel Water Coil(s)
Digit 10 - Design Sequence
Current Design Sequence
Digit 11 - Refrigeration Circuit
0 = Heating and Cooling Circuit
2 = Heating and Cooling Circuit w/Hot
Gas Reheat
3 = Heating and Cooling Circuit
w/Waterside Economizer
4 = Heating and Cooling Circuit
w/ Waterside Economizer and Hot
Gas Reheat (available only on 6-25
ton units)
Digit 12 - Blower Configuration
1 = Standard Blower
2 = High Static Blower
A = Drive Package A
B = Drive Package B
C = Drive Package C
D = Drive Package D
E = Drive Package E
F = Drive Package F
G = Drive Package G
H = Drive Package H
J = Drive Package J
Digit 13 - Freeze Protection
A = 20 Degree F Freezestat
B = 35 Degree F Freezestat
Digit 14 - Design Special
0 = Standard Design
S = Design Special
Digit 15 - Supply Air
Arrangement
B = Back Supply Air Arrangement
F = Front Supply Air Arrangement
L = Left Supply Air Arrangement
R = Right Supply Air Arrangement
T = Top Supply Air Arrangement
Digit 6 - Return Air
Arrangement
B = Back Supply Air Arrangement
F = Front Supply Air Arrangement
L = Left Return Air Arrangement
R = Right Return Air Arrangement
Digit 17 - Control Types
0 = Basic 24V Controls
D = Deluxe 24V Controls
C = Tracer ZN510 Controls
B = Tracer ZN524 Controls
Digit 18 - Tstat/Sensor Location
0 = Wall Mounted Location
Digit 19 - Fault Sensors
1 = Condensate Overflow Sensor
3 = Condensate Overflow and Filter
Maintenance Timer
6 = Condensate Overflow and Fan Status
Sensor
J = Fan Status, Filter Maintenance Timer
and Condensate Overflow Sensor
Digit 20 - Temperature Sensor
0 = None
1 = Entering Water Sensor
Digit 21 - Open
Digit 22 - Electric Heat
0 = None
1 = Internal Boilerless Electric Heat
4 = External Boilerless Control Electric
Heat
Digit 23 - Open
Digit 24 - Filter Type
1 = 1 Throwaway Filter
2 = 2 Throwaway Filter
4 = MERV 8
5 = MERV 13
Digit 25 - Acoustic Arrangement
0 = Enhanced Sound Attenuation
1 = Deluxe Sound Attenuation
Digits 26-36 Do Not Apply to
GEH & GEV
00000000000