WSHP-SVX01L-EN 5
Model Number Descriptions: 1½–6 Ton (EXH/EXV)
Digits 1-3 - Unit Configuration
EXH = High Efficiency Horizontal
EXV = High Efficiency Vertical
Digit 4 - Development Sequence
F = R-410A
Digits 5-7 - Nominal Capacity
Digit 8 - Voltage (Volts/Hz/
Phase)
Digit 9 - Heat Exchanger
1 = Copper-Water Coil
2 = Cupro-Nickel Water Coil
Digit 10 - Current Design
Sequence
Digit 11 - Refrigeration Circuit
0 = Heating and Cooling Circuit
2 = Heating and Cooling Circuit with
Hot Gas Reheat
3 = Heating and Cooling Circuit with
Waterside Economizer
Digit 12 - Blower Configuration
3 = ECM Motor
Digit 13 - Freeze Protection
0 = Standard (none)
A= 20°F freezestat
B= 35°F freezestat
Digit 14 - Open Digit = 0
Digit 15 - Supply-Air
Arrangement
B = Back Supply-Air Arrangement
L = Left Supply-Air Arrangement
R = Right Supply-Air Arrangement
T = Top Supply-Air Arrangement
Digit 16 - Return-Air
Arrangement
L = Left Return-Air Arrangement
R = Right Return-Air Arrangement
Digit 17 - Control Types
0 = Basic 24V Controls
D = Deluxe 24V Controls
C = Tracer ZN510 Controls
B = Tracer ZN524 Controls
Digit 18 - Thermostat/Sensor
Location
0 = Wall Mounted Location
Digit 19 - Fault Sensors
0 = No Fault Sensor
1 = Condensate Overflow Sensor
2 = Filter Maintenance Timer
3 = Condensate Overflow and Filter
Maintenance Timer
4 = Fan Status Sensor
6 = Condensate Overflow and Fan Status
H = Fan Status and Filter Maintenance
Timer
J = Fan Status, Filter Maintenance Timer
and Condensate Overflow Sensor
Digit 20 - Temperature Sensor
0 = No Additional Temperature Sensor
1 = Entering Water Sensor
Digit 21 - Open Digit
Digit 22 - Electric Heat
0 = No Electric Heat
1 = Internal Boilerless Electric Heat
4 = External Boilerless Electric Heat
Digit 23 - Open Digit
Digit 24 - Filter Type
1 = 1 Throwaway Filter
2 = 2 Throwaway Filter
4 = MERV 8
5 = MERV 13
Digit 25 - Acoustic Arrangement
0 = Enhanced Sound Attenuation
1 = Deluxe Sound Attenuation
Digits 26-36 - Does Not Apply to
EXH or EXV
00000000000 = Digits 26-36 are not
applicable to the EXH or EXV product
018 = 1½ Ton 042 = 3½ Ton
024 = 2 Ton 048 = 4 Ton
030 = 2½ Ton 060= 5 Ton
036 = 3 Ton 070= 6 Ton
1 = 208/60/1 4 = 460/60/3
2 = 230/60/1 7 = 265/60/1
3 = 208/60/3 8 = 230/60/3