TSC AUTO ID Technology Co., Ltd. 4 Copyright 2013 All Rights Reserved.
GAPDETECT
Description
This command feeds the paper through the gap sensor in an effort to determine the paper and gap
sizes, respectively. This command references the user’s approximate measurements. If the
measurements conflict with the actual size, the GAPDETECT command will not work properly. This
calibration method can be applied to the labels with pre-printed logos or texts.
Syntax
GAPDETECT [x,y]
Note:
If the x, y parameters are ignored then the printer will calibrate and determine the paper length
and gap size automatically.
See Also
GAP, SIZE, BLINEDETECT, AUTODETECT