TSC AUTO ID Technology Co., Ltd. 7 Copyright 2013 All Rights Reserved.
BLINE
Description
This command sets the height of the black line and the user-defined extra label feeding length each
form feed takes.
Syntax
Dot measurement
This command has been supported since V6.27 EZ and later firmware.
The height of black line either in inch or mm
0 ≤ m ≤ 1 (inch), 0 ≤ m ≤ 25.4 (mm)
The extra label feeding length
0 ≤ n ≤ label length
Note:
For metric system, there must be a space between parameter and mm.
When the sensor type is changed from “GAP” to “Black Mark”, please send the “BLINE”
command to the printer first.
200 DPI : 1 mm = 8 dots
300 DPI : 1mm = 12 dots
Example
Sample Code
English system (inch):
BLINE 0.20,0.50
Metric system (mm):
BLINE 5.08 mm,12.7 mm
See Also
SIZE, GAP