1.4 Power Connection
The power cut-off method of this product is a plug/socket connection, so
when using this product, it is recommended to equip with a suitable
switching device with sufficient breaking capacity (such as an air switch;
insulation voltage: 400V AC; rated current: 10A)
1.5 Special Consumables.
Fuse specifications:15A 250V 5×20mm Time-Lag glass body cartridge fuse
1.6 Stop Categories
A Stop Category 1 and a Stop Category 2 decelerates the robot with drive
power on, which enables the robot to stop without deviating from its
current path.
Safety Input
Description
Emergency Stop Button of the Three-Position
Enabling Device
Performs a Stop Category 1.
Safeguard Stop by CI of Control Box
Performs a Stop Category 2.
1.7 Maximum Speed
Mode
Typical Scenarios
Maximum Speed
Teaching mode
Live Control Page of UFACTORY Studio
250 mm/s
Automatic mode
Blockly/ IDE of UFACTORY Studio
500 mm/s