Configuration and activation
A31003-M2000-M103-2-76A9, 07/2014
3-9 Alarm and Emergency Call Configuration, Administrator Documentation
SHB_PNG-Konfig.fm
Configuration menu
8. Confirm with Save.
Time Alarm
The Time Alarm can be activated optionally. It is triggered if a timed alarm is not acknowledged
in time by the user.
For more information on alarm destinations please refer to Chapter 4, "Control ports and alarm
destinations".
Procedure:
1. Select the Additional Features icon in the main menu.
2. Select Configuration.
3. Enter the five-position service PIN and confirm with OK.
4. Select one of the three operating modes.
5. Select Alarms.
6. Select Time Alarm.
7. Change the values of the following parameters:
Response Time
BM/AM 10 ... 900 s 90 s
PNG 10 ... 90 s 90 s
Prealarm Time
BM/AM 0 ... 300 s 15 s
PNG 0 ... 30 s 15 s
Alarm Destination
BM -
1
112
AM/PNG (up to 32 digits) (blank)
1 The alarm destination is the same in Basic Mode of the M3 Plus for all alarms and is entered under "General Settings".
Parameters Operating Mode Value Range Standard Value
Activation BM/AM/PNG On/off Off
Response Time
BM/AM 1 ... 120 min 15 min
PNG 1 ... 15 min 15 min
Prealarm Time
BM/AM 0 ... 300 s 15 s
PNG 0 ... 15 s 15 s
Table 3-6 Parameter – Time Alarm
Parameters Operating Mode Value Range Standard Value
Table 3-5 Parameter – Man Down Alarm

Table of Contents

Other manuals for Unify OpenStage M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage M3 and is the answer not in the manual?

Unify OpenStage M3 Specifications

General IconGeneral
BrandUnify
ModelOpenStage M3
CategoryCell Phone
LanguageEnglish

Related product manuals