29
Copyright 2014 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
User-Specified Reread Delay
If you want to set your own length for the reread delay, scan the bar code below, then set the
delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then
scanning Save.
Scanner Time-Out
Scanner Time-Out powers down the scanner after the unit has been idle for the specified time.
To prevent the scanner from powering down, set this time-out to 0, or no timer. Scan Scanner
Time-Out, then set the time-out by scanning digits (from 0 - 999,999 ms) from the inside back
cover, then scanning Save.
Default = 1 ms.
Centering
Use Centering to narrow the scanner’s field of view to make sure that when the scanner is
hand-held, it reads only those bar codes intended by the user. For instance, if multiple codes
are placed closely together, centering will insure that only the desired codes are read.
Note: To adjust centering when the scanner is in the stand, see Presentation Centering (page
25).
If a bar code is not touched by a predefined window, it will not be decoded or output by the
scanner. If centering is turned on by scanning Centering On, the scanner only reads codes
that pass through the centering window you specify using the Top of Centering Window,
Bottom of Centering Window, Left, and Right of Centering Window bar codes.