Circuit Breakers and Fuses
The engine and boat’s electrical system is protected against current overload by a circuit breaker and fuses.
● If the circuit breaker trips, press button to reset.
● Replace any blown fuses.
NOTICE! Circuit breakers or fuses that repeatedly fail indicate a problem that requires immediate attention. See
your Volvo Penta dealer.
Fuse and Relay Box Layout
Several spare fuses and relays are located on the inside of the fuse and relay box cover. In case of malfunctioning
or faulty fuses and relays, use the spares provided.
23672
3.0GLP-J
A Trim Down Relay F3 Not Used
B Trim Up Relay F4 15 Amp Fuse (Ignition)
C Starter Relay F5 Not Used
D Not Used F6 Not Used
E Ignition Relay F7 40 Amp Fuse (Instrument Panel)
F1 Not Used F8 40 Amp Circuit Breaker (Trim Pump)
F2 10 Amp Fuse (Trim Control) F9 20 Amp Fuse (Starter)
4.3GLP-J, 5.0GL-J(F)
A Trim Down Relay F3 7.5 Amp Fuse (Fuel Pump)
B Trim Up Relay F4 15 Amp Fuse (Ignition)
C Starter Relay F5 Not Used
D Fuel Pump Relay F6 Not Used
E Ignition Relay F7 40 Amp Fuse (Instrument Panel)
F1 Not Used F8 40 Amp Circuit Breaker (Trim Pump)
F2 10 Amp Fuse (Trim Control) F9 20 Amp Fuse (Starter)
Troubleshooting