wc_tx002070gb.fm
129
E 3000 Burner Setup—Gas
7.8 Adjusting the Combustion Head
Requirements
Machine shut down
Machine cool
Procedure
Perform the procedure below to adjust the combustion head.
1. Open the access door and locate the burner.
2. Remove the burner assembly cover (a).
3. Remove nut (c) and open the burner.
4. Loosen screw (d).
5. Move the elbow (e) so that the edge of the air tube (f) coincides with the set
point number (“5”).
6. Tighten screw (d).
7. Close the burner and reinstall nut (c).
8. Reinstall the burner cover.
Result
The combustion head has now been adjusted.
wc_gr008960
c
wc_gr008977
a
wc_gr008968
d
wc_gr008498
f
d
e
“5”

Table of Contents