E 3000 Maintenance
8.2 Inspecting the HTF System and the Fuel System
Requirements
Machine shut down
Burner cool
HTF System
Hoses:
1. Rotate the hose reel brake T-handle counterclockwise to release the brake.
2. Unwind all the hose off the reel. Inspect the hose for leaks and/or damage.
3. Repair any leaks and repair/replace any damaged hoses. See topic Repairing a
Hose.
4. Turn on the machine and rewind the hose onto the reel.
5. Engage the brake by turning the T-handle clockwise.
Pump, motor, and hydronic heater:
1. Inspect the pumps and motor assemblies and associated plumbing for leaks
and/or damage.
2. Inspect hydronic heater and associated plumbing for leaks and/or damage.
3. Repair/replace any damaged components.
4. Repair any leaks.
Fuel System
Burner:
1. Inspect all fuel hoses and connections for leaks and/or damage.
2. Inspect the fuel filter and associated fuel hoses for leaks and/or damage.
3. Repair/replace any damaged hoses, pipes, or connectors.
4. Repair any leaks.
Fuel tank:
1. Inspect all fuel hoses running into and out of the fuel tank for leaks and/or dam-
age.
2. Repair/replace any damaged hoses, pipes, or connectors.
3. Repair any leaks.