RD 16 Maintenance
wc_tx001076gb.fm 69
4.5 Cleaning the Spray Bars
Background
Clogged or dirty spray bars can prevent water from spraying onto the
drums. If water spray is noticeably reduced or absent even though
there is water in the tank, then clean the spray bars.
Procedure
Follow the procedure below to clean the spray bars.
4.5.1 Locate the plugs (a) at the ends of each spray bar (b). Unscrew and
remove the plugs.
4.5.2 Flush the inside of the spray bar with clean water.
4.5.3 Reinstall one of the plugs, and again flush the inside of the spray bar
with clean water. Check for free flow of water through each spray hole
(c).
4.5.4 If any of the spray holes are blocked, use a small pointed object (i.e. a
stiff piece of wire) to remove the blockage.
4.5.5 Reinstall the second plug when all spray holes are clean.