RD 16 Maintenance
wc_tx001076gb.fm 79
4.15 Hydraulic Oil Level
See Graphic: wc_gr005895
A hydraulic oil level sightglass (29) is located on the side of the
hydraulic fluid reservoir.
While the machine is turned off, check that the hydraulic oil level is
visible at the middle level or higher in the sightglass. If it is not, add oil
through the filler port (20) inside the engine compartment. Use only
clean hydraulic oil.
Thoroughly clean the top of the filler cap before removing it from the
tank. Care should be taken to prevent small dirt particles from entering
the system.
If hydraulic oil continually needs to be added, inspect hoses and
connections for possible leaks.
4.16 Hydraulic Suction Strainer
See Graphic: wc_gr002959
A hydraulic strainer (14) is located in the hydraulic tank. This strainer
will not normally require service and does not need to be replaced
when changing the hydraulic oil.
wc_gr005895
20
29
14