48
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2354920
SPRINT XE
7.5.2.3 RESTARTING THE MANUAL POWDER SYSTEM
Procedure:
1. Check if the control unit is switched o .
2. Open the powder tank.
WARNING
Dust formation!
Risk of poisoning if inhaled.
Danger due to escaping dust, contamination of the device and device components.
The powder tank may only be lled to the halfway mark, because uidizing
increases the volume of powder.
3. Switch on the control unit and activate the "Powder Feed Quantity" function by pressing
the "Powder Quantity" button (36).
4. Adjust the powder quantity to 0% with the universal rotary controller (24).
5. Actuate the trigger and keep it actuated.
6. Adjust the uid air at the throttle until uidization is recognizable.
Note:
The uid air quantity is dependent on the powder condition.
Avoid a build up of powder dust (too much uid air) in the
powder tank!
7. Close the powder tank and check whether the exhaust air hose is leading in the
direction of the ventilation system of the powder coating booth.
To adapt the programs to the new applications proceed as described in the EPG-Sprint XE
control unit's operating manual.