January 2001/ version 1.4
WMOi3 Integrated Modem
confidential ©
17/61
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged
without prior written agreement. Ce document est la propriété exlcusive de WAVECOM. Il ne peut
être communiqué ou divulgué à des tiers sans son autorisation préalable.
Vibration
Test
Sinusoidal vibration
IEC 68-2-6.
No performance degradation or mechanical degradation
is allowed after test.
Vibration
Test
Random vibration
IEC 68-2-36.
No performance degradation or mechanical degradation
is allowed after test.
Shock Test IEC 68-2-27. No performance degradation or mechanical degradation
is allowed after test.
Bump Test IEC 68-2-29. No performance degradation or mechanical degradation
is allowed after test.
Humidity
Test
Corrosion test IEC
68-2-3.
No visible degradation of the product, both visual and
functionnal.
The unit is tested at room temperature and must be fully
operative for the main RF parameters.
Warehouse
Test
Low temperance IEC
68-2-1.
Under normal condition (room temperature) after the
test, the unit must behave in full conformity with the
main RF parameters specification.
Warehouse
Test
High temperature
IEC 68-2-2.
Under normal condition (room temperature) after the
test, the unit must behave in full conformity with the
main RF parameters specification.
Dust Test MIL-STD-810D,
method 510-3.
No visible dust in the visible areas. No more than 50
dust particules in the cabinet of the product. The unit,
tested at room temperature must be fully operative.
Light Test UV radiation and
temperature EDF
HN60E03.
Visual inspection on the discoloration and other
degradation effects such as cracks in the material of the
unit after the test.
Fall Test IEC 68-2-32.
Only minor casing degradation is allowed, with a
maximum dimension change of 1mm. The unit must
remain fully operative and full specification for the main
RF parameters.
Electro Static
Discharge
Test
IEC 1000-4-2. No performance degradation allowed after the test.
Salt Mist
Test
IEC 68-2-11 After the test, visual inspection on the unit.
Atmosphere
Test
Flowing mixed gas
corrosion. IEC 68-2-
60
After the test, visual inspection on the unit and inside.
Marking
Test
EN 60 950 After the test, visual inspection on the unit. No
degradation is allowed on the marking.
3.2 FTA Compliance
The WMOi3 has received a Full-Type Approval (according to normal MS
requirements) in the configuration using the internal SIM interface.
3.2.1 IMEI Number
GSM 900/1800:
TAC: 5 000 64
FAC: 11
Serial Numbers: 000000 to 999999

Table of Contents

Other manuals for Wavecom WMOi3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wavecom WMOi3 and is the answer not in the manual?

Wavecom WMOi3 Specifications

General IconGeneral
BrandWavecom
ModelWMOi3
CategoryModem
LanguageEnglish

Related product manuals