Digital Control Panel operation and settings
6
1 Digital Control Panel operation and settings
1.1 Operating and programming level 1
Higher
values
Chiller Control
Cool
Auto
Heat
Read-out
Blower speed
Lower values Set-up / programming
Cool cycle
mode
Automatic
mode
Heat cycle
mode
On / Off
Higher
values
(Sun)
Read-out
(0)
Lower values
(Snow flake)
Blower speed Function
(F)
Cool cycle
mode
Automatic
operation
Heat cycle
mode
On / Off
ON Push 1x, display will show ON. During first start-up display will also flash the
current frequency (50H = 50 Hz).
After INIT, finally the room temperature will appear. Air-blower or chilled
water pump (Premium only) will start.
Depending on controller setting unit will start in cooling or heating mode. In
case error codes appear, see trouble shooting.
OFF Push 1x, unit and display will automatically shut-off when running.
MEMO(NENO) Push 1x, to memorise new settings during programming.
RETURN Push 1x, display will return to room temperature when programming.
FUNCTION Push 1x, shows b.. for blower setting.
Push 2x, shows E.. or H.. for coil or water temperature.
Push 3x, shows CODE, enter code for access programming level 2.
(Default=64) Classic only
Change b.. or enter CODE by pushing up or down key.
NEXT LINE Push 1x, for next line and memorise new setting.
DOWN Push 1x will show actual setpoint, again to lower setpoint.
BLOWER SPEED Shows actual blower speed setting, bA automatic control or b1-b5 manual,
adjustable by up or down.
UP Push 1x will show actual setpoint, again to raise setpoint.
During operation failure codes might appear on the display (see troubleshooting), when these are solved,
controller will restart within 60 seconds.
When the same failure occurs 6 times within 30 minutes the unit will stop completely without restart, LEDs
will flash in the display until cause is solved. The counter is reset after 5 minutes of compressor operation.
Failure code A01 has a time delay of approximately 40 seconds to avoid cut-out during start-up.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Webasto BlueCool Classic and is the answer not in the manual?

Webasto BlueCool Classic Specifications

General IconGeneral
BrandWebasto
ModelBlueCool Classic
CategoryAir Conditioner
LanguageEnglish

Related product manuals