Repairs and Adjustments
Phaser 3100 MFP 04/08 4-15
REP 5 Retard Pad and Cork Pad
Parts List on: PL 8
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer supply
while performing tasks that do not need electricity. Electricity can cause death or injury. Moving
parts can cause injury.
Preparation
• Remove the feeder assembly, REP 4.
Removal
Rocking Plate:
1. Insert a screwdriver in the right slot as shown below and make a pivoting movement down-
wards without strain to remove the retard pad.
2. Repeat the previous step for the left slot of the retard pad, Figure 1.
Figure 1
3. Remove the feed roll assembly.