BROADSOFT PARTNER CONFIGURATION GUIDE YEALINK T4X IP PHONE 20-BD5476-00
©
2017 BROADSOFT INC. PAGE 33 OF 150
Step Command Purpose
Step 5 Enable the hold reminder feature for the line.
Example:
account.1.call_center.play_bw_hold_t
one_enable = 1
Enable the hold reminder
feature.
0 for Disabled
1 for Enabled
Step 6 Configure the interval to specify how long the call
center call information appears.
Example:
account.1.call_center.call_info_enab
le = 1
account.1.call_center.show_call_info
_time = 30
Enable the call center call
information feature.
0 for Disabled
1 for Enabled
Step 7 Configure the disposition code for the line.
account.X.bw_disp_code.Y = disposition code
account.X.bw_disp_code_name.Y = disposition
code name
Example:
account.1.call_center.disp_code_enab
le = 1
account.1.bw_disp_code.1 = 22
account.1.bw_disp_code_name.1 =
asleep
Enable account 1’s disposition
code feature.
0 for Disabled
1 for Enabled
The disposition code must
match one of the codes
configured on BroadWorks.
Value Y must be continuous,
with minimum and maximum as
1 and 100.
Step 8 Configure the customer originated trace feature.
Example:
account.1.call_center.trace_enable =
1
Enable the customer originated
trace for account 1.
0 for Disabled
1 for Enabled
Step 9 Configures the emergency escalation feature.
account.X.supervisor_info_code_name.Y =
supervisor name
account.X.supervisor_info_code_name.Y =
supervisor name
Example:
account.1.call_center.emergency_enab
le = 1
account.1.supervisor_info_code.1 =
supervisor number
account.1.supervisor_info_code_name.
1 =
supervisor name
Enable the emergency
escalation feature.
0 for Disabled
1 for Enabled
The supervisor number. The
supervisor number length must
be within 30 characters.
The supervisor name length
must be within 99 characters.
Value Y must be continuous,
with minimum and maximum as
1 and 100.
Step 10 Configure the queue status via the Power
Indicator LED.
Example:
account.1.call_center.queue_status_e
nable = 1
account.1.call_center.queue_status_l
ight_enable = 1
Enable the queue status
notification feature for account
1.
0 for Disabled
1 for Enabled
4.3.5 Call Recording Feature Configuration
Centralized Call Recording feature enables you to record all active calls. You can initiate
and control call recording process on your phone. The recording files are saved on the
server.
On the BroadWorks server, browse to Call Control Call Recording

Table of Contents

Other manuals for Yealink SIP-T46S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T46S and is the answer not in the manual?

Yealink SIP-T46S Specifications

General IconGeneral
ManualYes
Cables includedLAN (RJ-45)
Number of handles included1 pc(s)
MountingDesk/Wall
Handset typeWired handset
Product typeIP Phone
Product colorBlack
Voice codecsCNG, G.711Mu, G.711a, G.722, G.723.1, G.726, G.729ab, VAD, iLBC
Lines quantity16 lines
Phonebook capacity1000 entries
Number of VoIP accounts16
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 95 %
Display diagonal4.3 \
Display resolution480 x 272 pixels
AC adapter input voltage100 - 240 V
AC adapter output current2 A
AC adapter output voltage5 V
Dual-Tone Multi-Frequency (DTMF) modesIn-band, Out-of band, SIP info
Volume controlDigital
Number of programmable keys10
USB 2.0 ports quantity1
Ethernet LAN (RJ-45) ports2
Networking standardsIEEE 802.3af
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet LAN interface typeGigabit Ethernet
Supported network protocolsSIP v1, SIP v2, LLDP/CDP/DHCP, OpenVPN, IEEE802.1X, IPv6, FTP/TFTP/HTTP/HTTPS
Harmonized System (HS) code85171800
Weight and Dimensions IconWeight and Dimensions
Depth213 mm
Width244 mm
Height185 mm
Package depth255 mm
Package width274 mm
Package height128 mm