1-105
IM 04L51B01-01EN
Configuring the GX/GP
1
1.10 Setting the Conditions for Saving Data Files
Set the conditions for saving data files.
1.10.1 Setting the Save Directory, File Header, and File Name
Path
GX/GP: MENU key > Browse tab > Setting > Setting menu Data save settings
Web application: Config. tab > Data save settings
Hardware configurator: Data save settings
Description
Save directory
Setup Item Selectable Range or Options Default Value
Directory name
Character string (up to 20 characters,
A
a
#
1
)
DATA0
Directory name
Set the name of the directory on the storage medium for saving data.
Characters that cannot be used: ' ; " * / : < > ? \ |
Spaces are not allowed in the beginning or end of names.
Names cannot be all spaces.
Strings that cannot be used: AUX, CON, PRN, NUL, CLOCK, CLOCK$, COM0 to COM9,
LPT0 to LPT9
Note
Do not place a file with the same name as the directory name (“DATA0” by default) in the storage
medium for saving data.
File header*
Setup Item Selectable Range or Options Default Value
Characters
Character string (up to 50 characters,
A
a
#
1
)
—
* If the multi-batch function (/BT option) is enabled, see the multi-batch function manual (IM
04L51B01-03EN).
Characters
Enter a header comment to write into data files.
Data file name*
Setup Item Selectable Range or Options Default Value
Structure Date, Serial, Batch Date
Identified strings
Character string (up to 16 characters,
A
a
#
1
)
—
* If the multi-batch function (/BT option) is enabled, see the multi-batch function manual (IM
04L51B01-03EN).
Structure
Sets the structure of the file name when saving data.
Options Description
Date Serial number + specified string + date
Serial Serial number + specified string
Batch Serial number + batch (when using the batch function)
Identified strings
Set the user-assigned character string.
Characters that cannot be used: ' ; " * / : < > ? \ |