Chapter4ServiceConguration
Figure4-53UDLDCongurationInstance
lCongurationProcedure
zteA(cfg)#udldport17,18enable
zteB(cfg)#udldport17,18enable
lCongurationVerication
ThuJul116:07:092004UdldPort:17linkfailure
ThuJul116:07:092004UdldPort:18linkfailure
ThuJul116:07:102004Port:17linkdown
ThuJul116:07:102004HostTopologychanged
ThuJul116:07:102004Port:18linkdown
ThuJul116:07:102004HostTopologychanged
zteA(cfg)#showudldport17
Port17
Administrativeconfiguration:Enable
Portmode:Aggressive(Aggr)
Currentstate:Unidirectional-Detectedlinkfailure
Recoveryconfiguration:Disable
Recoverytimeinterval:30s
Messagetimeinterval:15s
Forcecheckconfiguration:Disable
Forcechecktime:30s,Remaining:0s
Noneighbourinformationstored
4.38TACACS+Conguration
TACACS+Overview
TerminalAccessControllerAccess-ControlSystemPlus(TACACS+)isdevelopedfrom
TACACSandXTACACS.ItisthelatestversionofTACACS(notcompatiblewiththe
previoustwoversions).ItisapopularAAAprotocolatpresent.
4-133
SJ-20120409144109-002|2012-07-02(R1.0)ZTEProprietaryandCondential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2918E and is the answer not in the manual?

Zte ZXR10 2918E Specifications

General IconGeneral
VLANs4K
Jumbo Frame9K
Power SupplyAC: 100~240V, 50~60Hz
Operating Temperature0°C~45°C
Storage Temperature-40°C~70°C
Operating Humidity10% to 90% non-condensing
Storage Humidity5%~95% (non-condensing)
Power Consumption<=25W