ABB relion REF615 User Manual

ABB relion REF615
404 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #315 background imageLoading...
Page #315 background image
RDRE1
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36
C37
C38
C39
C40
C41
C42
C43
C44
C45
C46
C47
C48
C49
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C60
C61
C62
C63
C64
TRIGGERED
OR6
B1
B2
B3
B4
B5
B6
O
OR
B1
B2
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR
B1
B2
O
OR
B1
B2
O
OR
B1
B2
O
OR
B1
B2
O
OR
B1
B2
O
CCBRBRF1_TRBU
EFLPTOC2_OPERATE
DARREC1_CLOSE_CB
X130_BI3_CB_OPENED
X130_BI2_CB_CLOSED
SECRSYN1_SYNC_OK
PHIPTOC1_OPERATE
PHLPTOC1_OPERATE
PHHPTOC1_OPERATE
EFLPTOC1_OPERATE
EFHPTOC1_OPERATE
EFIPTOC1_OPERATE
FRPFRQ3_OPERATE
FRPFRQ2_OPERATE
FRPFRQ1_OPERATE
PHPTOV2_OPERATE
PHPTOV1_OPERATE
PHPTUV1_OPERATE
PHPTUV2_OPERATE
ARCSARC1_OPERATE
ARCSARC2_OPERATE
ARCSARC3_OPERATE
NSPTOC1_OPERATE
NSPTOC2_OPERATE
DPHHPDOC1_OPERATE
DPHLPDOC1_OPERATE
T1PTTR1_OPERATE
ROVPTOV2_OPERATE
ROVPTOV1_OPERATE
DEFHPDEF1_OPERATE
DEFLPDEF1_OPERATE
CCBRBRF1_TRRET
PHLPTOC1_START
PHHPTOC1_START
EFLPTOC1_START
EFLPTOC2_START
EFHPTOC1_START
PHPTOV1_START
PHPTOV2_START
PHPTUV1_START
PHPTUV2_START
ROVPTOV1_START
ROVPTOV2_START
FRPFRQ1_START
FRPFRQ2_START
FRPFRQ3_START
HREFPDIF1_START
PHIPTOC1_START
DPHHPDOC1_START
DPHLPDOC1_START
EFIPTOC1_START
DEFHPDEF1_START
DEFLPDEF1_START
T1PTTR1_START
NSPTOC1_START
NSPTOC2_START
X130_BI1_EXT_OC_BLOCKING
CCSPVC1_FAIL
SEQSPVC1_FUSEF_U
ARCSARC1_ARC_FLT_DET
ARCSARC2_ARC_FLT_DET
ARCSARC3_ARC_FLT_DET
INRPHAR1_BLK2H
SEQSPVC1_FUSEF_3PH
SECRSYN1_SYNC_INPRO
SECRSYN1_CL_FAIL_AL
SECRSYN1_CMD_FAIL_AL
DARREC1_INPRO
DARREC1_UNSUC_RECL
DISTURB_RECORD_TRIGGERED
GUID-E051CE94-0FA6-4017-AD62-9DAD14D58501 V2 EN
Figure 467: Disturbance recorder
3.12.3.3 Functional diagrams for condition monitoring
Failures in current measuring circuits are detected by CCSPVC1. When a failure is
detected, it can be used to block current protection functions that measure the
calculated sequence component currents or residual current to avoid unnecessary
operation.
CCSPVC1
BLOCK FAIL
ALARM
CCSPVC1_FAIL
CCSPVC1_ALARM
GUID-5544B5AF-888D-4318-AF12-B69C37BCF99A V2 EN
Figure 468: Current circuit supervision function
The fuse failure supervision SEQSPVC1 detects failures in the voltage measurement
circuits at bus side. Failures, such as an open MCB, raise an alarm.
1MRS756378 S Section 3
REF615 standard configurations
REF615 309
Application Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB relion REF615 and is the answer not in the manual?

ABB relion REF615 Specifications

General IconGeneral
TypeFeeder Protection and Control Relay
Rated Frequency50/60 Hz
Control FunctionsCircuit breaker control, Disconnector control
ApplicationFeeder protection in utility and industrial power distribution systems
Communication ProtocolsIEC 61850, Modbus, DNP3
MountingFlush mounting
Operating Temperature-25°C to +55°C
Protection FunctionsOvercurrent, earth fault, undervoltage, overvoltage
Weight2.5 kg