Function IEC 61850 A B C D E F G H J K L N
IEC 61850-9-2 LE
sampled value
receiving (voltage
sharing)
8)9)
SMVRCV (1) (1) (1) (1) (1) (1) (1) (1)
Other
Minimum pulse timer
(2 pcs)
TPGAPC 4 4 4 4 4 4 4 4 4 4 4 4
Minimum pulse timer
(2 pcs, second
resolution)
TPSGAPC 1 1 1 1 1 1 1 1 1 1 1 1
Minimum pulse timer
(2 pcs, minute
resolution)
TPMGAPC 1 1 1 1 1 1 1 1 1 1 1 1
Pulse timer (8 pcs) PTGAPC 2 2 2 2 2 2 2 2 2 2 2 2
Time delay off (8 pcs) TOFGAPC 4 4 4 4 4 4 4 4 4 4 4 4
Time delay on (8 pcs) TONGAPC 4 4 4 4 4 4 4 4 4 4 4 4
Set-reset (8 pcs) SRGAPC 4 4 4 4 4 4 4 4 4 4 4 4
Move (8 pcs) MVGAPC 2 2 2 2 2 2 2 2 2 2 2 2
Generic control point
(16 pcs)
SPCGAPC 2 2 2 2 2 2 2 2 2 2 2 2
Analog value scaling
(4 pcs)
SCA4GAPC 4 4 4 4 4 4 4 4 4 4 4 4
Integer value move
(4 pcs)
MVI4GAPC 1 1 1 1 1 1 1 1 1 1 1 1
1, 2, ... = Number of included instances. The instances of a protection function represent the number of identical protection function blocks available in the
standard configuration.
() = optional
1) "Uo measured" is always used.
2) "Uo calculated" is always used.
3) One of the following can be ordered as an option: admittance-based E/F, wattmetric-based E/F or harmonics-based E/F.
4) "Io measured" is always used.
5) "IoB measured" is always used.
6) Master trip is included and connected to the corresponding HSO in the configuration only when the BIO0007 module is used. If additionally
the ARC option is selected, ARCSARC is connected in the configuration to the corresponding master trip input.
7) Power quality option includes current total demand distortion, voltage total harmonic distortion, voltage variation and voltage unbalance.
8) Available only with IEC 61850-9-2
9) Available only with COM0031...0037
3.1.1 Addition of control functions for primary devices and the use
of binary inputs and outputs
If extra control functions intended for controllable primary devices are added to the
configuration, additional binary inputs and/or outputs are needed to complement the
standard configuration.
If the number of inputs and/or outputs in a standard configuration is not sufficient, it
is possible either to modify the chosen IED standard configuration in order to release
some binary inputs or binary outputs which have originally been configured for other
purposes, or to integrate an external input/output module, for example RIO600, to the
IED.
The external I/O module’s binary inputs and outputs can be used for the less time-
critical binary signals of the application. The integration enables releasing some
initially reserved binary inputs and outputs of the IED’s standard configuration.
1MRS756378 S Section 3
REF615 standard configurations
REF615 41
Application Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB relion REF615 and is the answer not in the manual?

ABB relion REF615 Specifications

General IconGeneral
BrandABB
Modelrelion REF615
CategoryController
LanguageEnglish

Related product manuals