EasyManuals Logo
Home>ABB>Controller>S4Cplus

ABB S4Cplus Instruction

ABB S4Cplus
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
&DOLEUDWLRQ
3.2.4. Updating revolution counters
3HAC 16578-1 Revision: E42
© Copyright 2003-2007 ABB. All rights reserved.
8SGDWLQJUHYROXWLRQFRXQWHUV
*HQHUDO
This section details how to perform a rough calibration of each robot axis, i.e. updating the
revolution counter value for each axis, using the pendant.
6WHS0DQXDOO\UXQQLQJWKHURERWWRWKHFDOLEUDWLRQSRVLWLRQ
This procedure details the first step when updating the revolution counter; manually running
the robot to the calibration position.
:$51,1*
Axis 4 has no mechanical limitation! Cabling inside the manipulator may be damaged if axis
4 is oriented incorrectly when performing calibration of the robot!
&RUUHFWFDOLEUDWLRQSRVLWLRQRID[LVDQG
When running the robot to calibration position, it is extremely important to make sure that
axes 4 and 6 of the below mentioned robots are positioned correctly. The axes can be
calibrated at the wrong turn, resulting in wrong calibrated robot.
Make sure the axes are positioned according to the correct calibration values, not only
according to the calibration marks. The correct values are found on a label, located either on
the lower arm or underneath the flange plate on the base.
At delivery the robot is in the correct position, do NOT rotate axis 4 or 6 at power up before
the revolution counters are updated.
If one of the below mentioned axes are rotated one or more turns from its calibration position
before updating the revolution counter, the correct calibration position will be lost due to
uneven gear ratio. This affects the following robots:
$FWLRQ 1RWH
1. Select axis-by-axis motion mode.
2. Jog the robot to place the FDOLEUDWLRQPDUNV
within the tolerance zone.
IRB 140, 1400, 2400, 4400, 6600ID/
6650ID: Axes 5 and 6 must be positioned
together!
Shown in section &DOLEUDWLRQVFDOHVDQG
FRUUHFWD[LVSRVLWLRQRQSDJH.
3. When all axes are positioned, store the
revolution counter settings.
Detailed in section:
6WHS6WRULQJWKHUHYROXWLRQFRXQWHU
VHWWLQJZLWKWKH738RQSDJH
(RobotWare 4.0).
6WHS6WRULQJWKHUHYROXWLRQFRXQWHU
VHWWLQJZLWKWKH)OH[3HQGDQWRQSDJH
(RobotWare 5.0).
5RERWYDULDQW $[LV $[LV
IRB 140 Yes Yes
IRB 1600 No Yes
IRB 6400 / 200kg Yes No
IRB 6400R / 200kg Yes No
IRB 6600-175/2.55 Yes No
&RQWLQXHVRQQH[WSDJH

Other manuals for ABB S4Cplus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB S4Cplus and is the answer not in the manual?

ABB S4Cplus Specifications

General IconGeneral
BrandABB
ModelS4Cplus
CategoryController
LanguageEnglish

Related product manuals