Compact 5000 I/O Digital Modules
Catalog Numbers 5069-IA16, 5069-IB8S, 5069-IB8SK, 5069-IB16, 5069-IB16F, 5069-IB16K, 5069-IB6F-3W, 5069-OA16,
5069-OB8, 5069-OBV8S, 5069-OBV8SK, 5069-OB16, 5069-OB16F, 5069-OB16K, 5069-OW4I, 5069-OW16, 5069-OX4I
User Manual
Original Instructions
2
Table of Contents
Default Chapter
3
Table of Contents
3
Preface
11
Summary of Changes
11
Graphics Indicate Feature Support
12
Terminology
13
Additional Resources
14
Digital Module Operation in a Control System
17
Chapter 1 Controller and Software Compatibility
18
Controller Compatibility
18
Software Compatibility
18
Types of Modules
21
Module Overview
22
Local I/O Modules or Remote I/O Modules
24
Local I/O Modules
24
Remote I/O Modules
25
Secure Access to the System
28
Ownership
29
Multiple Owners of Compact 5000 I/O Digital
29
Input Modules
29
Configuration Changes in an Input Module with
30
Multiple Owners
30
Construct a System
31
Local I/O Modules
31
Remote I/O Modules
32
Reserve a Node Address
33
Power the Modules
34
Use a 5069-FPD Field Potential Distributor to
35
Establish New SA Power Buses
35
Power Requirements When You Use Compact 5000 I/O
37
Safety Modules
37
Configure the Modules
40
Connections with Compact 5000 I/O Digital Modules
40
Connections with Compact 5000 I/O Safety Modules
44
Requested Packet Interval
47
Connection over an Ethernet/Ip Network
48
Input Module Operation
49
Local Compact 5000 I/O Digital Input Modules
49
Trigger Events for Standard Input Modules
49
Remote Compact 5000 I/O Digital Input Modules
50
Output Module Operation
51
Local Compact 5000 I/O Digital Output Modules
52
Remote Compact 5000 I/O Digital Output Modules
53
Listen Only
56
Protected Operations
57
Considerations Specific to Safety Modules
58
Overall System Safety Function
59
Single-Channel or Dual-Channel Mode
59
Use with Safety Controllers
60
Determine Conformity
60
Obtain Firmware
61
Safety Precautions
62
Safety Application Requirements
63
Safe State
64
Configuration Signature and Ownership
65
Out-Of-Box State
66
Chapter 2
68
Input Module Compatibility
68
Output Module Compatibility
69
Software Configurable
70
Module Data Quality Reporting
71
Fault and Status Reporting
72
Module Inhibiting
73
Electronic Keying
74
More Information
74
Module Firmware
75
Producer/Consumer Communication
76
Use CIP Sync Time with Fast
77
I/O Modules
77
Timestamping
78
Rockwell Automation Publication 5069-UM004A-EN-P - April
79
Features Common to Compact 5000 I/O Digital Modules
68
Chapter 3 Multiple Input Module Types
82
Data Transfer at RPI or Change of State
83
Software Configurable Input Filters and Delays
84
Compact 5000 I/O Standard Input Modules
84
Compact 5000 I/O Safety Input Modules
85
Input Filter with Compact 5000 I/O Fast Input Modules
86
Module Health Diagnostic
87
Fault and Status Reporting
88
Compact 5000 I/O Standard Input Modules
88
Compact 5000 I/O Safety Input Module
89
Simple Count Mode
90
Sequence of Events Per Point Timestamping
91
Chatter Detection
92
Events
93
Event Definition
93
Independent Point Trigger
95
Pattern Match Trigger
96
Additional Event Considerations
97
Pulse Latching
98
Field Power Loss Detection
100
Short Circuit Protection
102
Diagnostics Triggered
103
Test Output Recovery after Overload or Short
104
Circuit to Ground Condition
104
Thermal Shutoff
105
Input Module Features
82
Chapter 4 Multiple Output Module Types
108
Module Health Diagnostics
109
Data Echo
110
Field Power Loss Detection
111
No Load Detection
113
Short Circuit Protection
115
Output Modules
115
Short Circuit Protection with Safety Output Modules
116
5069-OBV8SK Module
117
Thermal Shutoff
118
Ground Condition
118
Thermal Shutoff with Standard Output Modules
119
Thermal Shutoff with a Safety Output Module
120
Fault and Status Reporting
121
Compact 5000 I/O Standard Output Modules
121
Compact 5000 I/O Safety Output Modules
122
Output State Change Time
123
Configurable Channel-Level Output State in Program
123
Mode or Fault Mode
123
Connection Fault Handling
124
Output Behavior Immediately after a Connection
124
Fault
124
Fault State Duration after Connection Fault
125
Final Fault State Value
125
Output State Once Connection Is Re-Established
125
Forcing
126
Enable Forces
126
Disable or Remove a Force
127
Check Force Status
127
GSV Instruction
128
Time-Scheduled Output Control
129
Output Module
130
Isolated and Non-Isolated Varieties of Output Modules
132
Output Module Features
108
Chapter 5 Safety Input Module Features
133
Safety Application Suitability Levels
133
Use Test Output with a Safety Input
135
Single-Channel Mode
137
Safety Input Fault Recovery
138
Safety Input Delay Time
138
Muting Lamp Operation
141
Safety Output Module Features
143
Safety Application Suitability Levels
143
Safety Output with Test Pulse
144
Single-Channel Mode
146
Dual-Channel Mode
147
Safety Output Fault Recovery
148
Fault and Status Reporting
148
Rockwell Automation Publication 5069-UM004A-EN-P - April
149
Safety Module Features
133
Chapter 6 Before You Begin
150
Create a New Module
150
Discover Local I/O Modules
150
New Local I/O Modules
153
Discover Remote I/O Modules
155
New Remote I/O Module
157
Reserve an I/O Module Slot
159
Add the 5069-ARM Module to the Project
159
Delete the 5069-ARM Module from the Project
160
Edit the Module Configuration Common Categories
162
General Category
162
Connection Category
165
Module Info Category
166
Edit 5069-IA16 Module Configuration Categories
167
Points Category
167
Edit 5069-IB16 Module Configuration Categories
168
Counters Category
168
Points Category
169
Edit 5069-IB16F Module Configuration Categories
169
Counters Category
170
Points Category
171
Events Category
173
Time Sync Category
175
Edit 5069-IB6F-3W Module Configuration Categories
176
Counters Category
176
Points Category
177
Events Category
179
Time Sync Category
181
Edit 5069-OA16 Module Configuration Categories
182
Points Category
182
Edit 5069-OB8 Module Configuration Categories
183
Points Category
183
Edit 5069-OB16 Module Configuration Categories
184
Points Category
184
Edit 5069-OB16F Module Configuration Categories
185
Points Category
185
Edit 5069-OW4I Module Configuration Categories
186
Points Category
186
Edit 5069-OW16 Module Configuration Categories
187
Points Category
187
Edit 5069-OX4I Module Configuration Categories
188
Points Category
188
View the Module Tags
189
Configure a Standard Module
150
Chapter 7
192
Before You Begin
192
Create a New Module
192
New Local Safety Module
192
New Remote I/O Module
194
Edit the Module Configuration Common Categories
196
General Category
197
Connection Category
200
Safety Category
201
Module Info Category
202
Edit the 5069-IB8S and 5069-IB8SK Module
203
Configuration Categories
203
Input Points Category
203
Test Output Points Category
204
Edit the 5069-OBV8S and 5069-OBV8SK Module
204
Points Category
204
View the Module Tags
205
Replace a Safety Module
206
Set the SNN Manually
206
Reset to Out-Of-Box Configuration
208
Replace a Module in a Logix 5000 System
209
Configure and Replace Safety Modules
192
Appendix A Module Status Indicator
212
Compact 5000 I/O Standard Input Modules
213
Status Indicators
213
Compact 5000 I/O Standard Output Modules
215
Status Indicators
215
Compact 5000 I/O Safety Input Module Status
219
Indicators
219
SA Status Indicator
220
I/O Status Indicators
220
Compact 5000 I/O Safety Output Module Status
221
Indicators
221
SA Status Indicator
222
I/O Status Indicators
222
Use the Logix Designer Application for Troubleshooting
223
Warning Signal in the I/O Configuration Tree
223
Status and Fault Information in Module
223
Properties Categories
224
Module and Point Diagnostics
226
Logix Designer Application Tag Editor
228
Internalfault Triggered on the Safety Output Module
229
Rockwell Automation Publication 5069-UM004A-EN-P - April
230
Troubleshoot Your Module
212
Appendix B Name Conventions
232
Access the Tags
232
5069-IA16 Module Tags
233
Configuration Tags
233
Input Tags
234
5069-IB16 Module Tags
235
Configuration Tags
235
Input Tags
236
Output Tags
237
5069-IB16F Module Tags
238
Configuration Tags
238
Event Input Tags
240
Event Output Tags
242
Input Tags
243
Output Tags
246
5069-IB6F-3W Module Tags
247
Configuration Tags
247
Event Input Tags
249
Event Output Tags
251
Input Tags
252
Output Tags
255
5069-OA16 Module Tags
256
Configuration Tags
256
Input Tags
257
Output Tags
257
5069-OB8 Module Tags
258
Configuration Tags
258
Input Tags
259
Output Tags
259
5069-OB16 Module Tags
260
Configuration Tags
260
Input Tags
261
Output Tags
261
5069-OB16F Module Tags
262
Configuration Tags
262
Input Tags
263
Output Tags
265
5069-OW4I, 5069-OW16, and 5069-OX4I Module Tags
266
Configuration Tags
266
Input Tags
267
Output Tags
267
5069-IB8S and 5069-IB8SK Module Tags
268
Input Tags
268
Output Tags
269
5069-OBV8S and 5069-OBV8SK Module Tags
270
Input Tags
270
Output Tags
271
Module Tag Definitions
232
Appendix C
273
Before You Begin
273
5069-IB8S or 5069-IB8SK Module Wiring Diagrams
274
5069-OBV8S and 5069-OBV8SK Module Wiring Diagrams
277
Bipolar Mode
277
Sourcing Mode
281
Wiring Faults on Safety Modules
285
Compact 5000 I/O Safety Input Module Safety Data
288
Appendix D
289
Compact 5000 I/O Safety Output Module Safety Data
289
Index
291
Rockwell Automation Publication 5069-UM004A-EN-P - April
292
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Allen-Bradley 5069-OBV8S and is the answer not in the manual?
Ask a question
Allen-Bradley 5069-OBV8S Specifications
General
Brand
Allen-Bradley
Model
5069-OBV8S
Category
I/O Systems
Language
English
Related product manuals
Allen-Bradley 5069-OB16
296 pages
Allen-Bradley 5069-OF4
166 pages
Allen-Bradley 5069-OF8
166 pages
Allen-Bradley 5069-IF8
166 pages
Allen-Bradley 5069-IB16
296 pages
Allen-Bradley 5069-IB8S
296 pages
Allen-Bradley 5069-IB16F
296 pages
Allen-Bradley SLC 500 1746-NI4
28 pages
Allen-Bradley SLC 500 1746-NO4I
28 pages
Allen-Bradley SLC 500 1747-L511
28 pages
Allen-Bradley 1769-HSC
32 pages
Allen-Bradley 1734-IB8
221 pages