2-6 Controller Memory and File Types
Protecting Data Files
During Download
Data File Download Protection
Once a user program is in the controller, there may be a need to update
the ladder logic and download it to the controller without destroying
user-configured variables in one or more data files in the controller. This
situation can occur when an application needs to be updated, but the data
that is relevant to the installation needs to remain intact.
This capability is referred to as Data File Download Protection. The
protection feature operates when:
A User Program is downloaded via programming software
A User Program is downloaded from a Memory Module
Setting Download File Protection
Download File Protection can be applied to the following data file types:
Output (O)
Input (I)
Binary (B)
Timer (T)
Counter (C)
Control (R)
Integer (N)
String (ST)
Long Word (L)
Proportional Integral Derivative (PD)
Message (MG)
NOTE
The data in the Status File cannot be protected.

Table of Contents

Other manuals for Allen-Bradley micrologix 1500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley micrologix 1500 and is the answer not in the manual?

Allen-Bradley micrologix 1500 Specifications

General IconGeneral
BrandAllen-Bradley
Modelmicrologix 1500
CategoryController
LanguageEnglish

Related product manuals