Rockwell Automation Publication 750COM-UM009A-EN-P - May 2017 165
EtherNet/IP Objects Appendix D
11 Get/Set DPI Link USINT[3] Link (parameter or function block that is the source of the
value). (0 = no link)
12 Get Help Object Instance UINT ID for help text for this parameter
13 Get DPI Read Basic STRUCT of:
BOOL[32]
CONTAINER
CONTAINER
CONTAINER
CONTAINER
STRING[16]
STRING[4]
Descriptor (see page 167
)
Parameter value
Minimum value
Maximum value
Default value
Parameter name
Units (for example, Amps, Hz)
14 Get DPI Parameter Name STRING[16] Parameter name
15 Get DPI Parameter Alias STRING[16] Customer supplied parameter name.
16 Get Parameter Processing
Error
USINT 0 = No error
1 = Value is less than the minimum
2 = Value is greater than the maximum
18 Get International DPI Offline
Parameter Text
Struct of:
STRINGN
STRINGN
International parameter name
International offline units
19 Get International DPI Online
Parameter Text
Struct of:
STRINGN
STRINGN
International parameter name
International online units
Table 81 - Host DPI Parameter Object: Instance Attributes (continued)
Attribute ID Access Rule Name Data Type Description