Rockwell Automation Publication 750COM-UM009A-EN-P - May 2017 69
Configuring the Drive in a Logix System Chapter 3
Stratix 6000 (1783-EMS…)
The Stratix 6000 performs ‘Dynamic IP address Assignment by Port’ per the
settings on the DHCP Configuration tab:
Stratix 8000 (1783-MS…) / 8300 (1783-RMS…)
The Stratix 8000/8300 sets the IP address per the ‘DHCP Persistence’ tab:
One IP address is configured for each port on the switch (star topology - one
drive per port). If you have a ring topology, the IP address for drive is set via
other means, such as the HIM or last octet rotary switches on the drive/
communication. Firmware Supervisor and/or ADC can still be used and will
execute after the drive gets its IP address and ‘appears’ on the network to the
Logix controller.
Using Firmware Supervisor
The Logix Firmware Supervisor function has been extended to provide
firmware updates for the peripherals that are connected to the drive. You must
be online and in Program mode with the controller to load/store the Firmware
Supervisor settings. To configure the controller to check and refresh the correct
firmware for the drive and peripherals, perform the following steps: