Publication 2098-DU003B-EN-P — September 2006
Ultra3000 Digital Servo Drive Installation Manual 3
Page A-2
Replace the Ultra3000 (230V) Power Specifications table on page A-2
with the one shown below. The new table includes inrush current
specifications configured as Series A, B, or C.
Ultra3000 drive firmware revision 1.45 is required to support the
Series C hardware.
Ultraware software, version 1.63, is required to download
firmware to Series C drives containing the new power board.
Ultra3000 Drive (230V) Power Specifications
2098-DSD-005x-xx, 2098-DSD-010x-xx, and 2098-DSD-020x-xx
Specification
Description
2098-DSD-005 2098-DSD-010 2098-DSD-020
AC input voltage
(1)
100...240V rms single-phase
AC input frequency 47...63 Hz
AC input current
(2) (3)
Nom (rms)
230V ac (0-pk) max inrush
(4)
5 A
100 A - Series A or B
20 A - Series C
9 A
100 A - Series A or B
20 A - Series C
18 A
100 A - Series A or B
20 A - Series C
Continuous output current (0-pk) 2.5 A 5 A 10 A
Intermittent output current (0-pk) 7.5 A 15 A 30 A
Bus capacitance 1410 μF 1880 μF 1880 μF
Internal shunt resistance N/A N/A N/A
Shunt on N/A N/A N/A
Shunt off N/A N/A N/A
Bus overvoltage 400V dc 400V dc 400V dc
Energy absorption capability
115V ac input
230V ac input
93 J
38 J
125 J
51 J
Continuous power output
115V ac input
230V ac input
0.25 kW
0.5 kW
0.5 kW
1.0 kW
1.0 kW
2.0 kW
(1)
Specification is for nominal voltage. The absolute limits are ±10%, or 88...265V rms.
(2)
The 2098-DSD-005x-xx, -010x-xx, and -020x-xx (230V) drives are limited to:
Series A or B - one contactor cycle every two minutes.
Series C - one contactor cycle every 10 s for up to two minutes, not to exceed 12 cycles in five minutes.
(3)
Power initialization requires a short period of inrush current. Dual-element time delay (slow blow) fuses are recommended.
(4)
Inrush current-limiting circuitry is enabled within 3 s after removal of ac line power.
ATTENTION
The inrush current-limiting circuitry is limited in the number of
power cycles it can withstand within a set period of time. If you
exceed these limitations, the circuitry will be damaged.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Ultra3000 and is the answer not in the manual?

Allen-Bradley Ultra3000 Specifications

General IconGeneral
BrandAllen-Bradley
ModelUltra3000
CategoryServo Drives
LanguageEnglish

Related product manuals