Publication 2098-DU003B-EN-P — September 2006
4 Ultra3000 Digital Servo Drive Installation Manual
Page A-3
Replace the Ultra3000 (230V) Power Specifications table on page A-3
with the one shown below. The new table includes an updated value
in the bus capacitance field for 2098-DSD-030 drives.
Ultra3000 Drive (230V) Power Specifications
2098-DSD-030x-xx, 2098-DSD-075x-xx, and 2098-DSD-150x-xx
Specification
Description
2098-DSD-030 2098-DSD-075 2098-DSD-150
AC input voltage
(1)
100...240V rms
Single-phase
100...240V rms
Three-phase
AC input frequency 47...63 Hz
Main ac input current
(2) (3)
Nom (rms)
230V ac (0-pk) Max inrush
28 A
50 A
30 A
50 A
46 A
68 A
Auxiliary ac Input current
115V ac (rms) Nom
230V ac (rms) Nom
115V ac (0-pk) Max inrush
(4)
230V ac (0-pk) Max inrush
(4)
1.0 A
0.5 A
47 A
95 A
1.0 A
0.5 A
47 A
95 A
1.0 A
0.5 A
47 A
95 A
Continuous output current (0-pk) 15 A 35 A 65 A
Intermittent output current (0-pk) 30 A 75 A 150 A
Bus capacitance 2820 μF 4290 μF 7520 μF
Internal shunt resistance 35 Ω 16.5 Ω 9.1 Ω
Shunt on 420V dc 420V dc 420V dc
Shunt off 402V dc 402V dc 402V dc
Bus overvoltage 452V dc 452V dc 452V dc
Internal shunt
Continuous power
Peak power
50 W
4.5 kW
50 W
10 kW
180 W
18 kW
External shunt
Resistance
Continuous power
Peak power
30 Ω (-0/+5%)
2.4 kW
6 kW
16.5 Ω (-0/+5%)
4 kW
10 kW
9 Ω (-0/+5%)
8 kW
19 kW
Energy absorption capability
115V ac input
230V ac input
211 J
117 J
381 J
211 J
669 J
370 J
Continuous power output
115V ac input
230V ac input
1.5 kW
3 kW
3.75 kW
7.5 kW
7.5 kW
15 kW
(1)
Specification is for nominal voltage. The absolute limits are ±10%, or 88...265V rms.
(2)
The 2098-DSD-030x-xx, -075x-xx, and -150x-xx (230V) drives are limited to one contactor cycles per two minutes.
(3)
Power initialization requires a short period of inrush current. Dual-element time delay (slow blow) fuses are recommended.
(4)
400 μs half wave sine.
ATTENTION
The inrush current-limiting circuitry is limited in the number of
power cycles it can withstand within a set period of time. If you
exceed these limitations, the circuitry will be damaged.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Ultra3000 and is the answer not in the manual?

Allen-Bradley Ultra3000 Specifications

General IconGeneral
BrandAllen-Bradley
ModelUltra3000
CategoryServo Drives
LanguageEnglish

Related product manuals