TESTING
Ve ctor F® Se ries S ervice Ma nual M N- 46 89 5 R ev 1 7/ 20
70
Continued from previous page
7. Touch the Offsets icon j. The Offsets screen displays.
8. Touch the chamber that needs to be calibrated k. The Enter Offsets screen
displays.
Enter the offset number l from the calculation.
To determine the offset number, subtract the smaller number from the
larger number. If the multimeter number is larger, add a “+” in front of the
resulting number. If the chamber number is larger, add a “-” in front of the
resulting number.
Touch the check mark m.
Touch the green check mark n when finished.
Result The chamber thermocouple has now been calibrated.
O
ven Model
H
eater
s
Blo
w
e
r
s
Fa
n
s
Se
rvi
ce
Offsets
1 2 3 4
0° 0°
VMC-TS-010799
j
Offsets
1 2 3 4
0° 0°
Offsets (° F)
VMC-TS-010802
k
l
m
n