14 1791 999 13
3.4 Duress Code
Programme here the code which will disarm the panel and activate
the Personal Attack output. The output restores after entering a
user code.
3.5 Code Count
Programme the amount of times code 4 can be introduced. When set
to '99' code 4 is always operational. Setting to '0' disables the code.
3.6 êêOpen Zones On/Off
When this option is programmed to 'On' then a keyswitch user will
be able to view any open zones by pushing twice the [ê ] button.
3.7 Quick codes On/Off
When this option is programmed to 'On' it is possible to fast arm the
panel.
The following three keystroke sequences are possible :
[0] [ê] [4] Arms system with exit time.
[0] [ê] [5] Arms system immediately (no exit time).
[0] [ê] [7] Arms system partially (Part Set).
4. ZONES
4.1 Zone Type
Define here the typical function of each input.
TYPE FUNCTION
. Unused Input is not operational
. Tamper Input is 24Hrs operational. Activation of input causes
'internal bell' alarm in disarmed state and full alarm in
armed state. The input is automatically bypassed after
an alarm till the second valid entry of a user code.
output : tamper, alarm, int.bell, ext.bell, system clear, fire
reset
. P.A. Input is 24Hrs operational. Silent or audible Personal
Attack alarm is determined in function 6.2.1.
output : P.A., system clear, fire reset
. Key Input is 24Hrs operational to arm/disarm system. The
exact operation will be determined by the attributes allo-
cated in function 4.2. Use Pulse keyswitches if more
than one input is to be used as Key zone.
output : disarm/arm, buzzer, latch
. Fire Input is 24Hrs operational. Activation of zone will cause
the sirens to pulse on and of. The input is automatically
bypassed after an alarm till the second entry of a valid
user code.
output : fire, interior bell, exterior bell, system clear, fire
reset
Duress Code
Code Count
Open Zones
Quick Codes Off
Zone Type
CS350 Programming Functions

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aritech CS350 and is the answer not in the manual?

Aritech CS350 Specifications

General IconGeneral
BrandAritech
ModelCS350
CategoryControl Panel
LanguageEnglish

Related product manuals