Page #16 background image
14 1791 99916
Output Type
Install Remotes
Arm/Disarm Menu
TYPE FUNCTION
. A Alarm Switches with a perimeter alarm for the duration as
programmed in function 2.4.5. In this case the
exterior bell follows the A Alarm.
. Unused Output is not used.
5.2 Install Remotes
Only one keypad is installed when the panel is powered-up from
factory default. Additional keypads must be initialised by the panel
before they become active. When selecting [ü] install remotes, the
display will show the keypads which it recognizes, for example two
keypads: [Remote kk**]. Now enter [ü] again to initialize the other
keypad(s).
CS350 Programming Functions
6. MISCELLANEOUS
6.1 Arm / Disarm Menu
Programming of options associated with arming / disarming.
6.1.1 User Walk On/Off
When an input is open during arming of the panel, the interior
bell will give a short activation each time a zone is closed.
6.1.2 Forced Arm Opts
Determine here the' forced arming' conditions. Input(s) and
code(s) must have the 'In' attribute to be able to force arming of
the panel. Forced arming can be achieved in three ways.
a) Go to the [Forced Arm ] menu in the user mode and accept.
b) Arm the panel and enter [éé] when the display shows [Open
Zone(s)].
c) Arm the panel with a keyswitch while a 'forced arm' option
has been programmed.
Option Operation
. No forced arming Forced arming is not possible.
. Keep inhibits Open zones are omitted till the panel is dis-
armed.
. Clear when closed Open zones are omitted till they close
again. From that moment on they can detect
again.
. Clear after exit Open zones are omitted till the exit time has
expired, after which they can detect again.
6.1.3 Rearm Options
Define the condition of retriggering of bells.
Option Operation
. Always Rearm The same input when activated, will al-
ways retrigger sirens.
. Never Rearm The same input will not re-trigger the sirens.
. Rearm 1 to 8 times Limits the number of re-triggerings as
programmed.