14 1791 999 21
Without Engineer Lock programmed
1. Remove all power from the panel. Mains and the battery.
2. Remove the plug-on link (JP1) on the panel.
3. Restore the mains power.
4. The Display will prompt for the Language Default prefered. The display will change every two
seconds.
UK/IRL Press é1
NL Toets é2
F Taper é3
I Ins. é4
4. Enter at Keypad 1 the default operators code [0][1][1][2][2].
5. Enter at Keypad 1 the default engineer's code [0][1][2][7][8].
6. Replace the plug-on link and reconnect the battery.
With Engineer Lock programmed
1. Enter Engineer Mode using EXISTING Engineer code at Keypad 1.
2. Select 'Factory Prorgram Menu' from the miscellaneous section and scroll down to 'Default
Settings'. Enter accept ✔ .
NOTE: . When the existing engineer code is unknown, then the control panel must be
returned to the factory for reprogramming.
. The panel always powers up in Armed condition.
The use of operator "Quick Codes" can be enabled or disabled by setting "Quick Code" to ON or
OFF in the Use Menu.
The quick codes are as follows:
0¯4 Normal Set.
0¯5 Alarm Set (No Buzzer).
0¯7 Alarm Partguard Set.
Returning to Factory Default
Quick Codes