14 1791 999 19
The CS3503 control panel has been equipped with Aritech's new Perimeter and Dialler eXtended
programming option.
How It Works
When the panel is armed and not in alarm state, activating a perimeter zone will cause a Perimeter-
Alarm or Local Alarm. This means that both internal and external bells sound for a programmable
number of minutes (perimeter bell time).
l A Perimeter Alarm digi output will turn on and reset at the end of the perimeter bell cutout time.
l The main alarm digi will not turn on.
l Engineer reset and rearm option are not activated by Perimeter-Alarm.
l Perimeter-Alarms that occur during exit time, after silent PA etc. are treated like normal alarms.
l Perimeter-Alarms that occur during bell delay/cutout will merely set Perimeter-Alarm digi output.
l The output functionality is fixed... both bells go for the Perimeter-Time when a Perimeter-Alarm
happens.
Typical Application Example
WIRING
PROGRAMMING
OPERATION
Inertia Activation
'Perimeter' Alarm
'Full' Alarm
'Perimeter' Alarm
'Perimeter' Alarm
For programming see Programming
Map:
Zones è Zone attributes Ls for Shock (Zone 1-4)
La for Contacts(Zone 1-6)
Timers
è Bell times è perim. bell cutout ON/OFF
WEAPON AGAINST FALSE ALARMS
Consider, for example, the situation where the inertia sensor and magnetic contact are wired in series
and mounted on a window. When only the zone attributes Ls is added , then the panel will cause
a local alarm for inertia sensor activations and a full alarm when the window opens.
Shock Option
Ls
No Ls
Ls
No Ls
Contact Activation
'Full' Alarm
'Full' Alarm
'Perimeter' Alarm
'Perimeter' Alarm
PROGRAMMING AND OPERATION
Figure 6.
Zone Attribute
NO La
NO La
La
La
Peridiax Feature