KEY ZONE ATTRIBUTES
. Fs Full set. Keyswitch fully arms system.
. Ps Part set. Keyswitch partially arms system.
. Us Unset.Keyswitch disarms system.
. Pu Pulse.Keyswitch used must be a pulse type. Allows
arming/disarming with multiple keyswitches in a sys-
tem.
. Qs Quick set. Keyswitch arms panel without exit time.
4.3 Shock Zones
Input 1 to 4 can be programmed to analyse enertia shocks (e.g. GS610).
Two types of attack can be calibrated for. Heavy attacks ( 'gross'
level) and small repetitive attacks ('pulse' count). The pulse count
ismonitored after the first triggering in a window of 30s with 1s
intervals.
4.4 Zone Names
Programme here personalised names for each input.
(See page. 20 for example.)
4.5 Loop Type
Inputs can be configured to detect alarm contact activations only
('Alarm') or alarm and tamper violations within the same loop ('Dual').
5. OUTPUTS / REMOTES
5.1 Output Type
Define here the typical function of each output (1 to 6).
TYPE FUNCTION
. Disarm/Arm Reflects the control panel's arm/disarm status.
. Alarm Switches with intrusion and tamper alarm
(Tamper only when armed).
. PA Switches with PA alarm and / or Duress alarm.
. Fire Switches with a fire alarm.
. Tamper Switches with a 24Hrs and / or a tamper alarm.
. Latch Switches after exit time and / or walk test. Resets
with disarm or start of entry time.
Used withlatching sensors.
. Fire Reset Switches with second entry of a valid user code
after an alarm or after leaving the user log.
. Buzzer Follows the buzzer operation of the keypad.
. Interior Bell Follows the interior bell status.
. Exterior Bell Follows the exterior bell alarm time.
. Partguard Switches when control panel is part set.
. System Clear Reflects the system status according to the
optionsprogrammed in function 6.8.
. Trouble Indicates a system error : E²PROM error, line fault,
RKP fault, low battery, mains failure. The RKP will
display the cause of trouble.
Zone Attributes
Shock Zones
Zone Names
Loop Type : Alarm
Output Type
CS350 Programming Functions