FlexiROC T35 R/T40 R 4 Daily checks
30 No: 3171473547.1 en
Check point Inspection Instructions
!
NOTE: The
return oil
pressure
gauge will
show reliable
readings once
the oil has
reached a
temperature
of at least 40º
C (104ºF)
Hydraulic pressure Visual check Observe the pressure gauges to
make sure no abnormal pres-
sure arises
Table10: Functionality test.
For further instructions, see: Maintenance instructions
4.5 Function test while drilling
4.5.1 Checks
Check point Inspection Instructions
Sensors on the feed beam Limit position sensor/Calibration
sensor
Check the function of the
sensors
Rock drill hydraulic hoses Abnormal vibration Check the accumulators, for fur-
ther instructions see "Mainten-
ance instructions for rock drill".
Rock drill Shank adapter Make sure that oil trickles out
between the front and the ad-
apter.
Display for engine and direction
instruments
Display window Make sure no faults are indic-
ated. If a fault indication is
shown, stop the drill rig and rec-
tify the fault
Dust collector (DCT) Suction ability and filter cleaning In the event of dust build-up:
Check the filter in the filter
holder, the suction hose and the
drill-steel support gasket.
Drill rig Complete drill rig Check for signs of leaks
Hydraulic oil filter/Pressure
gauge
Pressure gauge panel Check for clogging by reading
the pressure in the return oil fil-
ter with the pressure gauge. If