FlexiROC T35 R/T40 R 6 Operating
81 No: 3171473547.1 en
Switching off the engine
Repeatedly bypassing delayed shutdown (DES) of the engine damages the DEF injector.
Each time delayed shutdown is bypassed it is recorded in the event log in the rig's control
system.
6.5 Stopping the diesel engine
!
NOTE: If the engine is hot, run it at idling speed for a couple of minutes before switch-
ing off.
1.
Unload the compressor. Switch S180A, position (c).
!
NOTE: NOTICE! The engine speed must be lowered to idling be-
fore the compressor is discharged.
2.
Set the position selector S130 (D) on the remote control box to tramming (h).
3.
To turn off the engine:
a.
Turn the ignition key to OFF. Ignition key S139. The engine may run at idling
speed for a few minutes. See the section Delayed shutdown (DES) for informa-
tion. Turn the key to position (P) to bypass DES.