FlexiROC T35 R/T40 R 9 Angle instruments
113 No: 3171473547.1 en
e Reset: Resetting the drilled length instrument.
Before the start of each hole, the drill bit should be
positioned against the ground. Use the arrow keys
to mark the button by the symbol and press Enter.
The button will then become blue. Current drilled
length should show 0. The display will continue to
show the angle instrument menu. This reset is
also available in the drilled length instrument's
menu.
f Graphic: The graphic shows deviation from the
desired inclination via a red line drawn in the dir-
ection of the deviation. The feeder spike must be
positioned in the opposite direction of the line to
reduce the deviation. When the feeder is set with
the desired amount of inclination, only a red dot is
shown in the centre of the graphic.
!
NOTE: If the total deviation of
the lateral inclination and the
forwards/backwards inclination
exceeds 3º, the lamp on the
side of the display window will
light red.
g Activating Auto Zoom: When the deviating angle
is less than 1º, the outer circle changes over to in-
dicate 1º instead of 5º.
Table40: Directional instrument - graphic display mode
!
NOTE: Remember that the desired angle values should always be specified in relation
to the setting of the sight. If the sight is not to be used, it should be set straight ahead
and the desired values adjusted to 0.
9.1.2 Laser plane instrument (option)
As a supplement to the drilled length instrument, a laser plane can be used as the refer-
ence level instead of the local ground level using a laser beam and a receiver on the drill
rig.
This requires that the distance between the drill bit and the laser receiver be entered when
the instrument is installed (see the section "Calibration"). Once the laser receiver on the
rock drill cradle has passed the laser plane, the indicated drilled length is related to the
laser plane instead of ground level. The indicated drilled length will then "jump" up to the
pre-programmed value and continue measurement from there. The laser beam must be
positioned in such a way that nothing comes between the laser beam and the laser re-
ceiver on the drill rig.
Menus
The laser plane function is activated in the drilled length menu. Function indication is down
in the status field of the display.