Operator’s instructions
5. Operating
55
Note
Manual cold start: If cold start (optional equipment) is installed, the hydraulic
pumps are disengaged when the engine is started. The hydraulic pumps are
engaged when the engine speed reaches 1200 rpm. In very cold weather the
engine may need to be warmed up for a longer time with disengaged pumps. In
which case, activate manual cold starting with button (14) before the ignition key
is turned to ignition position. At which point, the hydraulic pumps remain deacti-
vated until the button is released.
6. Once the engine has started, release the Ignition key , which will spring back to
DRIVE POSITION (c).
Note
Should the engine fail to start, stop trying after 20 seconds and wait one minute
before trying again.
7. Check the hydraulic oil temperature (must be preheated to at least 20 °C (68 °F)).
Note
If any of the fault indicator lamps on the diesel panel light up, turn off the engine
and rectify the fault indicated by the symbol that is on.
Stopping the diesel engine
N.B.
Allow the engine to idle a few minutes before turning it off if it is warm.
1. All controls to NEUTRAL position.