Installation Manual 16 Document #: LTRT-83506
Mediant 1000
3. Peel off the adhesive, anti-slide rubber feet and stick one in each anti-slide groove.
Figure 2-5: Peeled-off Rubber Foot
4. Flip the device over again so that it rests on its underside and place it in the required
position on a desktop.
2.3.2 Installing the Device in a 19-inch Rack
The device can be installed in a standard 19-inch rack by implementing one of the following
methods:
Placing it on a pre-installed shelf in a 19-inch rack (recommended method).
Attaching it directly to the rack’s frame using the device's integral front mounting
brackets and the user-adapted rear mounting brackets (not supplied). This method is
required for racks that don't provide shelves.
Rack Mount Safety Instructions
When installing the chassis in a rack, implement the following safety
instructions:
Elevated Operating Ambient Temperature: If installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient temperature. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) of
45°C (113°F).
Reduced Air Flow: Installation of the equipment in a rack should be
such that the amount of air flow required for safe operation on the
equipment is not compromised.
Mechanical Loading: Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven
mechanical loading.
Circuit Overloading: Consideration should be given to the connection of
the equipment to the supply circuit and the effect that overloading of the
circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be
used when addressing this concern.
Reliable Earthing: Reliable earthing of rack-mounted equipment should
be maintained. Particular attention should be given to supply connections
other than direct connections to the branch circuit (e.g., use of power
strips.)

Table of Contents

Other manuals for AudioCodes MediaPack MP-11 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-11 Series and is the answer not in the manual?

AudioCodes MediaPack MP-11 Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-11 Series
CategoryGateway
LanguageEnglish

Related product manuals