Installation Manual 50 Document #: LTRT-83506
Mediant 1000
¾ To load (or restore) the ini file:
1. Click the Browse button, navigate to the folder in which the ini file is located, select the
file, and then click Open; the name and path of the file appear in the field beside the
Browse button.
2. Click the Load INI File button, and then at the prompt, click OK; the device uploads
the ini file and then resets (from the cmp version stored on the flash memory). Once
complete, the 'Enter Network Password' dialog box appears, requesting you to enter
your user name and password.
3.7 Restoring Factory Default Settings
You can use the device's hardware Reset button to restore all the device's configuration
settings to factory defaults, including the device's IP address and Web interface's login user
name and password. These default settings include factory defaults as well as user-defined
defaults (refer to the device's User's Manual).
Notes:
• The device resets to the software version (cmp file) saved on its flash
memory.
• For additional methods to restore default settings, refer to the User's
Manual.
¾ To restore the device to factory default settings:
With a paper clip or any other similar pointed object, press and hold down the Reset
button (located on the CPU module) for at least 12 seconds (no more than 25
seconds); the device restores to factory default settings.