SP00D00490 2020-01-08| Robert Bosch GmbH
Instructions for use | ACS 763/863 | 65 en
6.4 Evacuation of the A/C system of the
vehicle
WARNING: to prevent injuries while working
with the refrigerant, read and follow the
instructions and warnings in this manual,
and wear protective clothing, such as safety
glasses and gloves.
1. Call up the Main Menu.
2. Select
.
3. Enter the service data and confirm with
(see chapter 6.1).
4. Accept the default 5 minute vacuum time (20
minutes for ACS 863-OE) or enter the desired
vacuum time using the number buttons.
5. Select
to continue.
i The software offers the possibility of performing
a leak check after the vacuum. Set whether to
perform or not perform the leak check function.
Only on ACS 863-OE, at the end of vacuum a leak
check of 10 minutes is performed automatically.
! The process stops if the pressure rises above 0.35bar
(5 psi). Recover refrigerant before proceeding.
6. Connect both service hoses to the vehicle service
connections and open the valves of the service
hoses turning the ring nuts clockwise.
7. Select
to continue.
8. The station generates a vacuum in the A/C system
for the programmed time interval.
9. The station at the end of the vacuum test performs a
leak check.
10. The station stops at the end of the specified time
interval displaying the test result.
i Select to print the vacuum information.
Select
to return to the Main Menu.
6.5 Hoses flushing
WARNING: to prevent injuries while working
with the refrigerant, read and follow the
instructions and warnings in this manual,
and wear protective clothing, such as safety
glasses and gloves.
! If the next vehicle on which to perform the work
contains a type of oil different from the oil of the
previous vehicle, it is advisable to flush the service
hoses to remove traces of residual oil in order to
prevent contamination.
1. Call up the Main Menu.
2. Select
.
3. Select .
4. Select Functions.
5. Select Flush Hoses.
The display shows Connect the hoses to
WKHÀXVKFRQQHFWLRQVDQGRSHQWKH
valves.
6. Connect the service hoses to the flushing
connections as shown.
1
Fig. 18: Hoses flushing
1 Flushing connections
7. Open the valves of the service hose connections
turning the ring nuts clockwise.
8. Select to start the hose cleaning procedure,
which lasts three minutes, followed by a recovery.
Once the flushing is complete, a message ap-
pears on the display indicating that the hoses
flushing is completed.
9. Select
to exit and return to the Functions Menu.
10. Close the valves of the connections turning the ring
nuts counter-clockwise.

Table of Contents

Other manuals for Bosch ACS 763

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch ACS 763 and is the answer not in the manual?

Bosch ACS 763 Specifications

General IconGeneral
BrandBosch
ModelACS 763
CategoryAir Conditioner
LanguageEnglish

Related product manuals