18 B94x/B93x Settings menu
Use the Settings menu to turn Watch mode on or off, set the system
date and time, view and change schedules, set keypad brightness and
volume, and show the time in the keypad display.
18.1 Watch Mode
You can use Watch Mode to monitor select points with the security
system turned off. Each time points are faulted (door or window is
opened), the keypad chimes once and shows the point text for 60
seconds. The control panel does not generate alarms in this mode
except 24-hour alarms (fire, panic, etc.).
Use this function in residential systems to monitor entries or exits in
your home. In commercial systems it can serve as a door chime to alert
you when a customer or delivery person enters your business.

Table of Contents

Other manuals for Bosch B8512G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B8512G and is the answer not in the manual?

Bosch B8512G Specifications

General IconGeneral
ModelB8512G
CategoryControl Panel
Power Supply12 VDC
SeriesG Series
Areas8
PGM Outputs on Board8
On-board EthernetYes
Wireless SupportYes
ManufacturerBosch
Input Voltage16.5 VAC
Users500
Communication FormatsIP, GSM, PSTN
CompatibilityCompatible with Bosch detectors, keypads, and communication modules