Control Panels Trouble events | en
25
Bosch Security Systems B.V. 2019.06 | 07 | F.01U.307.371
If the system is on, the display shows the number of points with
troubles and the name for each point.
8.3.1 Silence user and burglary trouble events
Press ENTER to silence the trouble tone.
8.3.2 View user and burglary trouble events
After a user enters a passcode, the name of the point in trouble
continues to scroll through the display. Use /NEXT to scroll text
manually. Events scroll from oldest to newest.
8.4 System trouble events
Examples of system trouble displays include Service AC Failure and
Service Battery Low. These displays appear on all keypads in the system.
All system trouble displays begin with SERV or Service. The Service text
clears only after the faulted condition is corrected.
Press ENTER to silence the trouble tone.

Table of Contents

Other manuals for Bosch B8512G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B8512G and is the answer not in the manual?

Bosch B8512G Specifications

General IconGeneral
ModelB8512G
CategoryControl Panel
Power Supply12 VDC
SeriesG Series
Areas8
PGM Outputs on Board8
On-board EthernetYes
Wireless SupportYes
ManufacturerBosch
Input Voltage16.5 VAC
Users500
Communication FormatsIP, GSM, PSTN
CompatibilityCompatible with Bosch detectors, keypads, and communication modules