3
SPECIFICATIONS
Power Requirements: 90 to 264 VAC (50/60 Hz) at 0.4A
Battery Operation: (
Models 205 and 210 only
) CAM-350 Type 12 volt 2000 mAh (2.0 Ah)
Enclosure Type, Size: Model 200 - Panel Mount, NEMA 12/IP52:
5 11/16"W x 2 13/16"H x 7 7/8"D (144mm W x 72mm H x 200mm D)
Models 205/210 v- NEMA 4X/IP66:
9 3/16"W x 7 1/2"H x 3 1/8"D (233mm W x 191mm H x 79mm D)
Weight: 8.2lbs -
(9.6lb with battery)
Operating Environment: Temperature: 14 to 104 ºF (-10 to +40 ºC)
Humidity: 90% non-condensing (maximum)
Display: 6-digit, 0.6" high, 7-segment LED
Sensitivity: 0.056 uV/V/d (0-3.3 mV/V input)
This equipment is manufactured in accordance with recommendations
set for a Class
III
device by the National Conference on Weights and
Measures, Measurement Canada and OIML R-76.
Signal Input Range: 1.0 mV min. to 40 mV max. (with dead load boost)
Transducer Excitation:
(Jumper selectable)
12 VDC (
all models
)
8 VDC - Battery operation (
Models 205 and 210 only
)
Number of Load Cells: 8 each, 350 OHM minimum resistance
Load Cell Cable Length: 1500 feet maximum. Consult factory for other requirements
30 feet maximum without sense lines
Resolution: 1 part in 100,000 displayed, normal mode
1 part in 1,000,000 internal
Capacities: 100 to 10,000 divisions commercial,
Up to 200,000 divisions non-commercial
Tare Capacity: Scale Capacity
Division Value: 1, 2, or 5 x 10, 1, 0.1, 0.01, and 0.001, commercial
0 to 99, non-commercial
Sample Rate: 1 to 50 samples per second, selectable
Auto Zero Range: 0.5 or 1 through 9 divisions
Weighing Units: Tons, Pounds, Pounds-Ounces, Ounces, Metric Tons, Kilograms, Grams
Keypad: Membrane type with 7 color-coded keys (22 keys on Model 210)
Standard I/O: (1) Bi-directional RS232 and 20mA and (1) RS232/20mA output only
Optional I/O: 14 bit Analog Output (0 to 10v, 4 to 20mA)
Standard Features:
Push button tare function Gross, tare, net conversion
Selectable key disable Hi-Resolution mode
Adjustable filtering Gross and Net accumulators
Remote input lines for Zero, Tare, Gross and Print (1000 feet maximum)
Programmable print format using Visual Print (2, available )
SMA level 2 compliant serial communications
(For more information see http://www.scalemanufacturers.org)
Field re-programmable via PC interconnection
Test feature (performs display and internal tests)
Battery Operation and Auto Shutoff & Sleep mode (
Models 205 and 210 only
)
Additional Model 210 Standard Features:
Keypad tare function Count feature Time and Date
Three Preset Weight Comparators or Checkweigher (setup selectable)
Optional Features:
Column Mounting available (
Models 205 and 210
)
Analog Output (
All Models
) Special Filtering (
All Models
)

Other manuals for Cardinal 200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 200 Series and is the answer not in the manual?

Cardinal 200 Series Specifications

General IconGeneral
BrandCardinal
Model200 Series
CategoryAccessories
LanguageEnglish

Related product manuals