218
<string 32> - Enter the MEP name used. This name can be up to 32 characters long.
mepid - Specify the MEP ID used.
<int 1-8191> - Enter the MEP ID used. This value must be between 1 and 8191.
md - Specify the maintenance domain name.
<string 22> - Enter the maintenance domain name. This name can be up to 22 characters
long.
md_index - Specify the maintenance domain index.
<uint 1-4294967295> - Enter the maintenance domain index value. This value can be
between 1 and 4294967295.
ma - Specify the maintenance association name.
<string 22> - Enter the maintenance association name. This name can be up to 22
characters long.
ma_index - Specify the maintenance association index.
<uint 1-4294967295> - Enter the maintenance association index value. This value can
be between 1 and 4294967295.
ttl - (Optional) Specify the link trace message TTL value. The default value is 64.
<int 2-255> - Enter the link trace message TTL value. This value must be between 2 and 255.
pdu_priority - (Optional) The 802.1p priority to be set in the transmitted LTM. If not specified, it
uses the same priority as CCMs sent by the MA.
<int 0-7> - Enter the PDU priority value. This value must be between 0 and 7.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To transmit an LTM:
DGS-3120-24TC:admin# cfm linktrace 00-01-02-03-04-05 mepname mep1
Command: cfm linktrace 00-01-02-03-04-05 mepname mep1
Transaction ID: 26
Success.
DGS-3120-24TC:admin#
19-19 show cfm linktrace
Description
This command is used to show the link trace responses. The maximum link trace responses a
device can hold is 128.
Format
show cfm linktrace [mepname <string 32> | mepid <int 1-8191> md [<string 22> | md_index
<uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]] {trans_id <uint>}
Parameters
mepname - Specify the MEP name used.
<string 32> - Enter the MEP name used. This name can be up to 32 characters long.
mepid - Specify the MEP ID used.
<int 1-8191> - Enter the MEP ID used. This value must be between 1 and 8191.

Table of Contents

Other manuals for D-Link xStack DGS-3120 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link xStack DGS-3120 Series and is the answer not in the manual?

D-Link xStack DGS-3120 Series Specifications

General IconGeneral
BrandD-Link
ModelxStack DGS-3120 Series
CategorySwitch
LanguageEnglish

Related product manuals