xStack
®
DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide
694
Parameters
unit - (Optional) Specify the Switch unit ID to be displayed.
<unit_id> - Enter the unit ID value. This value must be between 1 and 6.
Restrictions
None.
Example
To display DRAM utilization:
DGS-3120-24TC:admin#show utilization dram
Command: show utilization dram
Unit 1 DRAM utilization :
Total DRAM : 131072 KB
Used DRAM : 128128 KB
Utilization : 97 %
CTRL+C ESC q Quit SPACE n Next Page p Previous Page r Refresh
68-5 show utilization flash
Description
This command is used to show the flash memory utilization.
Format
show utilization flash {unit <unit_id>}
Parameters
unit - (Optional) Specify the Switch unit ID to be displayed.
<unit_id> - Enter the unit ID value. This value must be between 1 and 6.
Restrictions
None.
Example
To display FLASH utilization: