Indoor Unit (RA Models) Si18-525B
140 Function
7.9 INTELLIGENT EYE
This is the function that detects existence of humans in the room by a human motion sensor
(INTELLIGENT EYE) and reduces the capacity when there is no human in the room in order to
save electricity.
Processing 1. Detection method by Intelligent Eye
This sensor detects human motion by receiving infrared rays and displays the pulse wave
output.
A microcomputer in an indoor unit carries out a sampling every 20 msec. and if it detects 10
cycles of the wave in one second in total (corresponding to 20msec.× 10 = 100msec.), it
judges human is in the room as the motion signal is ON.
2. The motions (for example: in cooling)
When a microcomputer doesn’t have a signal from the sensor in 20 minutes, it judges that
nobody is in the room and operates the unit in temperature shifted 2°C from the set
temperature. (Cooling : 2°C higher, Dry: 1°C higher and Auto : according to the operation
mode at that time.)
1In case of Fan mode, the fan speed reduces by 50 rpm.
If the sensor detects the outputs 10 times/sec.
or more, it judges humans exist.
1sec
sampling (20msec)
High
Low
ON
OFF
Sensor output
(Human motion)
Human detection
signal
(R2821)
ON
OFF
RESET.
Cooling : Set temp. + 2˚C
Heating : Set temp. - 2˚C
Human detection
signal
20 min. 20 min.
within 20
minutes.
40 min.
MaxHz
MinHz
0Hz
Compressor
speed
The lower limit by detecting
human.
(Prohibition of thermostat-off)
ON
OFF
ON
OFF
Operation
OFF
Fan speed (+1)
Set speed - 50 rpm
Set speed Set speed
in case of
thermostat-off
Frequency at set temp. + 2˚C
Set temp.
(R2822)
Remote controller
Intelligent Eye
button

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin D-Series and is the answer not in the manual?

Daikin D-Series Specifications

General IconGeneral
HSPF RatingUp to 10.0
Cooling Capacity9, 000 - 36, 000 BTU/h
Heating Capacity9, 000 - 36, 000 BTU/h
Energy Efficiency Ratio (EER)Up to 12.5
Sound Level19 - 50 dB (Indoor), 49 - 60 dB (Outdoor)
Noise Level19 - 50 dB (Indoor), 49 - 60 dB (Outdoor)
Power Supply208/230V, 1-phase, 60Hz