1-15
1.4.5 Compressor, Fan Motor, Valve Function
Frozen Mode
Component Name Full Cool Modulation
Cooling
OFF
------ Notes -----
1 EFM operates at
RS-5.0
2 High pressure
control
3 EFM operates
H only or
H / L change
automatically
EEV fully open: 420 pls
EMV fully open: 300 pls
DMV fully open: 760 pls
Motor
Compressor
CM7,8
Max.130 rps 20130 rps OFF
Evaporator fan motor
EFM HL 1 LL
Condenser fan motor
CFM H/L/OFF 2 H/L/OFF 2 OFF
Solenoid
Valve
Liquid solenoid valve LSV ON ON OFF
Economizer solenoid valve
ESV ON ON OFF
Hot gas solenoid valve HSV OFF OFF OFF
Reheat solenoid valve RSV OFF OFF OFF
Modulation
Valve
Electronic expansion valve
EEV8
2100% 2100% 0%
Economizer modulation valve
EMV8
2100% 2100% 0%
Discharge modulation valve
DMV8
100% 100% 100%
Chilled Mode
Dehumidification mode
Component
Name
Full Cool Modulation
Cooling
OFF
Heating Dehumid.
Motor
CM7, 8
Max.130 rps 20130 rps OFF 2095 rps 2095 rps
EFM H H/L 3 H/L H/OFF H
CFM H/L/OFF 2 H/L/OFF 2 OFF OFFL/H 5 HL/OFF 6
Solenoid
Valve
LSV ON ON OFF OFFON/OFF 4 ON
ESV ON ON/OFF OFF OFFON 4 OFF
HSV OFF OFF OFF ONON/OFF 4,5 OFF
RSV OFF OFF OFF OFF ON
Modulation
Valve
EEV8
2100% 2100% 0% 0%036% 4 2100%
EMV8
2100% 2100% 0% 0%2424% 4 0%
DMV8
100% 100% 100%
0%0100% 4
13100% 5
20100%
Defrost Mode
Component
Name
Pumpdown Defrost
------ Notes -----
4 Charging control
5 Release control
6 CFM may become L/OFF in some case to
increase dehumidification capacity.
7 Compressor may reduce its rotation speed
prior to take protection control when
the protection control activated in some
reason.
8 Compressor rotation speed rps and
EEV, EMV, DMV opening pls are
displayed in panel. Refer to 3 Sensor
information in paragraph 2.3.
Motor
CM7, 8
Max.50 rps 2095 rps
EFM H/L/OFF 2 OFF
CFM H OFFL/H 5
Solenoid
Valve
LSV ON OFFON/OFF 4
ESV OFF OFFON 4
HSV OFF ONON/OFF 4,5
RSV OFF
OFFON/OFF 4,5
Modulation
Valve
EEV8
0% 0%036% 4
EMV8
0% 0%024% 4
DMV8
100%
0%0100% 4
13100% 5
0101-22LX10F11BEn.indd1-150101-22LX10F11BEn.indd1-15 2014/11/1916:40:302014/11/1916:40:30
https://daikin-p.ru

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin LX10F11B and is the answer not in the manual?

Daikin LX10F11B Specifications

General IconGeneral
BrandDaikin
ModelLX10F11B
CategoryInverter
LanguageEnglish

Related product manuals